900-LFC Loa sub active 18" Meyer Sound
Tính năng nổi bật
|
ACOUSTICAL1 |
|
|
Operating Frequency Range2 |
30 Hz – 125 Hz |
|
Frequency Response3 |
32 Hz – 115 Hz ±4 dB |
|
Phase Response |
40 Hz – 110 Hz ±30° |
|
Linear Peak SPL4 |
133 dB with crest factor >10 dB (M-noise), 133 dB (Pink noise), 134.5 dB (B-noise) |
|
COVERAGE |
|
|
|
360° (single unit); varies with number of units and configurations |
|
TRANSDUCERS |
|
|
Low Frequency |
One 18-inch, dual-coil, long-excursion cone driver; 2& OMEGA; nominal impedance |
|
AUDIO INPUT |
|
|
Type |
Differential, electronically balanced |
|
Maximum Common Mode Range |
±15 V DC, clamped to earth for voltage transient protection |
|
Connectors5 |
XLR 5-pin female input with male loop output; XLR 3-pin female connectors available to accommodate only balanced audio (no RMS signals) |
|
Input Impedance |
10 kΩ differential between pins 2 and 3 |
|
Wiring |
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamped network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal - Pin 4: RMS Pin 5: RMS Case: Earth ground and chassis |
|
Nominal Input Sensitivity |
6.0 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music |
|
Input Level |
Audio source must be capable of producing +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker |
|
AMPLIFIER |
|
|
Type |
Two-channel, open-loop, class D |
|
Total Output Power6 |
3100 W peak |
|
THD, IM, TIM |
< 0.02% |
|
Cooling |
Convection |
|
AC POWER |
|
|
Connectors |
powerCON 20 input with loop output |
|
Automatic Voltage Selection |
90–265 V AC, 50–60 Hz |
|
Safety Rated Voltage Range |
100–240 V AC, 50–60 Hz |
|
Turn-on and Turn-off Points |
90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC |
|
CURRENT DRAW |
|
|
Idle Current |
0.60 A rms (115 V AC), 0.49 A rms (230 V AC), 0.63 A rms (100 V AC) |
|
Maximum Long-Term Continuous Current (>10 sec) |
4.9 A rms (115 V AC); 2.5 A rms (230 V AC); 5.2 A rms (100 V AC) |
|
Burst Current (<1 sec)7 |
8.8 A rms (115 V AC), 4.7 A rms (230 V AC), 11.0 A rms (100 V AC) |
|
Maximum Instantaneous Peak Current |
18.2 A peak (115 V AC), 9.2 A peak (230 V AC), 20.6 A peak (100 V AC) |
|
Inrush Current |
< 20 A peak |
|
RMS NETWORK |
|
|
|