Cal 32/64/96 Loa Column Meyer Sound - Giá Call

 Tình trạng: Chờ order
 Mã sản phẩm: Cal 32/64/96
 Đã xem: 20.869
 Giá: 0₫

 

ACOUSTICAL1

Operating Frequency Range2

100 Hz 16 kHz

 

Frequency Response3

 

105 Hz 15 kHz ±4 dB

 

Phase Response

 

230 Hz 16.9 kHz ±45°

 

Linear Peak SPL4

CAL 96 at 90 m (295 ft), CAL 64 at 60 m (196 ft), CAL 32 at 30 m (98 ft):

 

101 dB with 18.5 dB crest factor (M-noise), 98 dB (Pink noise), 100 dB (B-noise)

COVERAGE

Horizontal Coverage

12

 

Vertical Coverage

 

Variable, to 30° in increments

 

Vertical Steering

 

±30° in increments

 

Vertical Beam Splits

CAL 96: Top split, bottom split CAL 64: Center split

CAL 32: None

TRANSDUCERS

 

Low Frequency

CAL 96: (24) 4-inch cone drivers CAL 64: (16) 4-inch cone drivers CAL 32: (8) 4-inch cone drivers

 

High Frequency

CAL 96: (72) 20 mm tweeters CAL 64: (48) 20 mm tweeters CAL 32: (24) 20 mm tweeters

AMPLIFIER

Type

Multichannel class D, one channel per driver

 

Number of Channels

 

96 (CAL 96); 64 (CAL 64); 32 (CAL 32)

 

Cooling

 

Convection and forced air

AUDIO/CONTROL

Analog Audio

(3) Phoenix 6-pin male connectors for balanced audio input and loop output

 

Digital Audio5

 

(1) Phoenix 6-pin male connector for AES/EBU input

 

Ethernet and AVB

AVB-enabled Ethernet ports for integrated audio streaming, beam control and RMS monitoring via Compass control software. Supports communication of AVB timing data and audio signals via AAF packets (AVTP Audio Format) and communication of AVB clock signals via CRF packets (Clock Reference Format).

 

Processing6

 

Mute, gain, 5-band parametric EQ, and delay, stored in four onboard presets

 

Logical I/O

Phoenix 6-pin male connector, recalls onboard presets, reports relay closures (and openings) for fault reports; Phoenix 5-pin male connector, triggers emergency mute and input override

 

Display

 

OLED button displays CAL’s network addresses during startup or when the button is pushed

AC POWER

Connector

powerCON 20

 

Safety Rated Voltage Range

 

100–240 V AC, 50–60 Hz

 

Turn-on and Turn-off Points

 

90 V AC turn-on; 264 V AC turn-off