Leopard Loa Line Array Đôi 9" Meyer Sound
Tính năng nổi bật
ACOUSTICAL1 |
|
Operating Frequency Range2 |
55 Hz – 18 kHz |
Phase Response |
92 Hz – 18 kHz ±30 degrees |
Linear Peak SPL3 |
133.5 dB with 18 dB crest factor (M-noise), 130 dB (Pink noise), 134.5 dB (B‑noise) |
COVERAGE |
|
Horizontal Coverage |
110° |
Vertical Coverage |
Varies, depending on array length and configuration |
TRANSDUCERS |
|
Low Frequency |
Two 9‑inch long‑excursion cone drivers; 2 Ω nominal impedance |
High Frequency |
One 3‑inch diaphragm compression driver coupled to a constant‑directivity horn through a patented REM® manifold; 4 Ω nominal impedance |
AUDIO INPUT |
|
Type |
Differential, electronically balanced |
Maximum Common Mode Range |
±15 V DC, clamped to earth for voltage transient protection |
Connectors |
XLR 5‑pin female input with male loop output; XLR 3‑pin female connectors available to accommodate only balanced audio (no RMS signals) |
Input Impedance |
10 kΩ differential between pins 2 and 3 |
Wiring4 |
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamped network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal ‑ Pin 4: RMS (polarity insensitive) Pin 5: RMS (polarity insensitive) Case: Earth ground and chassis |
Nominal Input Sensitivity |
6.0 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music |
Input Levels |
Audio source must be capable of producing +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker |
AMPLIFIERS |
|
Type |
3‑channel, open‑loop, class D |
Total Output Power5 |
3900 W peak |
THD, IM, TIM |
<0.02% |
Cooling |
Convection |
AC POWER |
|
Connector |
powerCON 20 input with loop output |
Automatic Voltage Selection |
90–265 V AC |
Safety Rated Voltage Range |
100–240 V AC, 50–60 Hz |
Turn‑on and Turn‑off Points |
90 V AC turn‑on, no turn‑off; internal fuse‑protection above 265 V AC |
CURRENT DRAW |
|
Idle Current |
0.46 A rms (115 V AC); 0.35 A rms (230 V AC); 0.49 A rms (100 V AC) |
Max Long‑Term Continuous Current (>10 sec) |
3.0 A rms (115 V AC); 1.5 A rms (230 V AC); 3.4 A rms (100 V AC) |
Burst Current (<1 sec)6 |
4.4 A rms (115 V AC); 2.3 A rms (230 V AC) 5.5 A rms (100 V AC) |
Maximum Instantaneous Peak Current |
12.6 A peak (115 V AC); 6.3 A peak (230 V AC); 14.5 A peak (100 V AC) |
Inrush Current |
<20 A peak |
Sản phẩm tương tự
Mini Line Array AR10 + AR18B Dòng Active China Công Suất Liên Tục 4200W HBK SOUND
55,790,000₫
Còn hàng