UPJ-1P Loa nguồn điểm 10" Meyer Sound
Tính năng nổi bật
ACOUSTICAL1 |
|
Operating Frequency Range2 |
55 Hz - 20 kHz |
Frequency Response3 |
66 Hz - 18 kHz ±4 dB |
Phase Response |
750 Hz - 18 kHz ±45° |
Linear Peak SPL4 |
125 dB with 18 dB crest factor (M-noise), 122.5 dB (Pink noise), 125 dB (B-noise) |
COVERAGE5 |
|
|
80° x 50° (rotatable horn) |
TRANSDUCERS |
|
Low Frequency |
One 10-inch cone driver with neodymium magnet; 4 Ω nominal impedance |
High Frequency |
One 3-inch diaphragm compression driver; 16 Ω nominal impedance |
AUDIO INPUT |
|
Type |
Differential, electronically balanced |
Maximum Common Mode Range |
±15 V DC, clamped to earth for voltage transient protection |
Connectors6 |
XLR 3-pin female input with male loop output; optional 5-pin XLR connectors accommodate both balanced audio and RMS signals |
Input Impedance |
10 kΩ differential between pins 2 and 3 |
Wiring |
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal - (optional polarity reversal switch)7 Case: Earth ground and chassis |
Nominal Input Sensitivity |
0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music |
Input Level |
Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker. |
AMPLIFIER |
|
Type |
Two-channel complementary MOSFET output stages (class AB/bridged) |
Total Output Power7 |
550 W peak |
THD, IM, TIM |
< 0.02% |
Cooling |
Forced air cooling over amplifier heat sink |
AC POWER |
|
Connector |
powerCON 20 input with loop output |
Automatic Voltage Selection |
90–264 V AC |
Safety Rated Voltage Range |
100–240 V AC, 50–60 Hz |
Turn-on and Turn-off Points8 |
90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC |
CURRENT DRAW |
|
Idle Current |
0.41 A rms (115 V AC); 0.33 A rms (230 V AC); 0.42 A rms (100 V AC) |
Maximum Long-Term Continuous Current (>10 sec) |
3.2 A rms (115 V AC); 1.6 A rms (230 V AC); 3.7 A rms (100 V AC) |
Burst Current (<1 sec) |
5 A rms (115 V AC); 2.5 A rms (230 V AC); 5.8 A rms (100 V AC) |
Maximum Instantaneous Peak Current |
17 A pk (115 V AC); 8.5 A pk (230 V AC); 20 A pk (100 V AC) |
Inrush Current |
15 A pk (115 V AC); 13 A pk (230 V AC); 15 A pk (100 V AC) |
RMS NETWORK (OPTIONAL) |
|
|
Equipped with two-conductor twisted-pair network, reporting all operating parameters of amplifiers to system operator’s host computer. |