Loa Monitor Meyer Sound Blue Horn System - Giá Call
Tính năng nổi bật
Hệ thống loa kiểm âm liền công suất cao cấp Meyer Sound Bluehorn
ACOUSTICAL |
|
Operating Frequency Range1 |
20 Hz – 22 kHz |
Frequency Response2 |
22 Hz – 22 kHz ±4 dB |
Phase Response |
25 Hz – 22 kHz ±45° |
Linear Peak SPL3 |
130 dB (M-noise), 127 dB (Pink noise), 129 dB (B-noise) |
COVERAGE |
|
Horizontal Coverage |
80° |
Vertical Coverage |
50° |
TRANSDUCERS |
|
Low Frequency |
One 18 in cone driver; nominal impedance: 4 Ω |
Low Frequency |
One 12 in cone driver; nominal impedance: 2 Ω |
High Frequency |
One 4 in diaphragm compression driver; nominal impedance: 12 Ω |
AUDIO INPUT |
|
Type |
Differential, electronically balanced |
Connectors |
XLR 3-pin female input with male XLR loop output |
Input Impedance |
10 kΩ differential between pins 2 and 3 |
Wiring |
Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal – Case: Earth ground and chassis |
Nominal Input Sensitivity |
10 dBV (3.2 V rms) continuous is typically the onset of limiting for noise and music |
AMPLIFIER |
|
Type |
Class D, Two-channel (Bluehorn); One-channel (Bluehorn Subwoofer) |
Total Output Power4 |
1300 W peak (Bluehorn); 900 W peak (Bluehorn Subwoofer) |
THD, IM, TIM |
< 0.02% |
Cooling |
Convection, with recessed heat sink |
AC POWER |
|
Connectors |
powerCON 20 input with loop output to loop between the Bluehorn and the Bluehorn Subwoofer |
Voltage Selection |
Automatic, continuous from 90–265 V AC |
Safety Rated Voltage Range |
100–240 V AC, 50–60 Hz |
Turn-on/off Points |
90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC |
CURRENT DRAW BLUEHORN |
|
Bluehorn Idle Current |
0.23 A rms (115 V AC); 0.19 A rms (230 V AC); 0.24 A rms (100 V AC) |
Bluehorn Subwoofer Idle Current |
0.26 A rms (115 V AC); 0.16 A rms (230 V AC); 0.30 A rms (100 V AC) |
Bluehorn Max Long-Term Continuous Current (>10 sec) |
1.58 A rms (115 V AC); 0.83 A rms (230 V AC); 1.78 A rms (100 V AC) |
Bluehorn Subwoofer Max Long-Term Continuous Current (>10 sec) |
1.4 A rms (115 V AC); 0.7 A rms (230 V AC); 1.6 A rms (100 V AC) |
Bluehorn Burst Current (<1 sec)5 |
3.1 A rms (115 V AC), 1.4 A rms (230 V AC), 3.6 A rms (100 V AC) |
Bluehorn Subwoofer Burst Current (<1 sec)6 |
2.7 A rms (115 V AC), 1.1 A rms (230 V AC), 3.0 A rms (100 V AC) |
Bluehorn Ultimate Short-Term Peak Current |
12.0 A peak (115 V AC), 8.0 A peak (230 V AC), 12.4 A peak (100 V AC) |
Bluehorn Subwoofer Ultimate Short-Term Peak Current |
9.0 A peak (115 V AC), 6.0 A peak (230 V AC), 10.0 A peak (100 V AC) |
Bluehorn/Bluehorn Subwoofer Inrush Current |
< 20.0 A peak |